The SBC i-Color combines boost control and sensor display features in one beautiful package. It includes a state of the art digital controller which controls two highly efficient sequential solenoids, ensuring minimum overshoot on peak boost and a stable boost pressure. If you are interested in the SBC i-Color's display capabilities but do not require boost control, then the Blitz MMD i-Color is right for you!

Features of the product

  • Boost control & power meter function.

An added function, the Result graph, which displays the results of power, torque, boost, and A/F overlapping to each other on one screen. It has a function as al logger according to the RPM to compare a maximum of three channels on the horizontal axis that are power, torque, boost and A/F.

  • The ultimate boost controller

The known full auto function evolves further in the SBC i-D series. A still more precise control is added to the auto boost setup. In addition to the new full auto function in which the self-learning method can be chosen in three steps, a boost according to the RPM and speed is possible to setup to match on all the stages.

  • Full color (65.000 colors)

The graphics that the full color display made it possible are; such as displaying from analog to digital meter, graph comparison display and a possibility to produce a variation of back ground images. If the optional TEMP sensor and PRESS sensor are connected, it is also possible to display water temperature or oil temperature and oil pressure. If the optional A/F Box is connected you will be able to display real time A/F ratio.

Monitoring functions

  • Digital display:

A total of 12 data (Boost, Tacho, Speed, Power, Temp (Oil/Water), Fuel Press, Oil Press, Data 1 ~3 (A separate harness is necessary) can be monitored and it can display simultaneously on screen a maximum of six data.

※A/F can be displayed at the AUX port or at the external voltage port Data 1 ~3.

※The sensors (required) are available separately.

  • Analog display:

The Boost, Tacho, Speed, Power, Temp (Oil/Water), A/F, Fuel Press and Oil Press are reproduced as an analog meter image at the LCD. It can monitor a maximum of 4 data, including the digital displays at the screen, and the boost set up is at will. Moreover, the background can also be chosen from a white, black, carbon, and blue.

  • Multi-angle display function

The display of the LCD can be set as left, right and perpendicular (the LCD at the top) operation angles. By selecting any one of these three angles, the switches also change automatically to the related angle.

  • Convenient functions

It has a full load of convenient functions, such as a peak display, independent warning setup by source, maximum of 10 minutes of record/replay function (replay function can convert the unit displayed), back light adjustment, dimmer function, contrast adjustment and language selection.

  • Optional A/F display function

If the optional A/F amplifier unit is connected, the A/F ratio can be measured and monitored, which can compare with boost or other sources. Thus, the boost setting can be broadened.

Regarding the boost controller

  • Sequential valve control:

Two-solenoid valves operate sequentially depending on the valve-open ratio. Mainly, the first valve will do most of the work at low valve-open ratio and at high valve-open ratio; the second valve will come to play.

  • Automatic correction of boost pressure (Initial learning):

It will automatically correct to the desired boost pressure that has been configured. A C mark will change color from RED to WHITE when the correction cycle (DUTY value) reaches the desired value. While the C mark is lighted, the SCRAMBLE MODE or the SPEED MAP MODE will not take effect on the used channel. However, the boost control will take effect even if the C mark does not change to WHITE color. This time, to perform the initial learning smoother, the normal, mild and slow function has been added. The Automatic correction of boost pressure is not applicable on manual mode.


Part # Year/Model Price  
15061 SBC-I Color Twin Solenoid $720.40

Optional SBC iColor Sensors

Note: There are 2 plugs for optional sensors. One is strictly for Temperature and the other is for EITHER Pressure OR A/F. The unit is NOT able to display both Pressure and A/F.

It is possible to display, record, and replay by inputting an external voltage of 0-16V up to three channels. It is possible to change the voltage scale from -999 ~9999. It is also possible to arbitrary setup the value. Therefore, it can be used to record the throttle voltage, airflow voltage, water temp and replay for reference as a setting tool. The external voltage input harness is sold separately.


Part # Year/Model Price  
15063 SBC iColor Optional Air/Fuel Box $477.5
19210 SBC iColor Optional Temperature Sensor $117
19211 SBC iColor Optional Pressure Sensor $117
15053 SBC iColor Optional External Voltage Harness $45



Screen Shots
SBC iColor Opening Sequence (1) SBC iColor  Opening Sequence (2) SBC iColor  Opening Sequence (3) SBC iColor Icon Menu
Opening Opening Opening Icon Menu
SBC iColor Dual Digital SBC iColor Dual Digital Warn SBC iColor Six-Fold SBC iColor Tacho Map
Dual Digital Dual Digital Warn Six-Fold Tacho Map
SBC iColor (Blue Background) SBC iColor (White Background) SBC iColor Needle Meter (Carbon Background) SBC iColor Needle Meter (Warning)
Needle Meter BL Needle Meter WH Needle Meter CB Needle Meter Warn
SBC iColor Power Graph (3) SBC iColor Power Graph(2) SBC iColor Result Graph SBC iColor Boost Graph
Power Graph Tri Power Graph Result Graph ALL Boost Graph
SBC iColor SBC iColor Boost Setup SBC iColor Limit-off Turned Off  
Volt Input Setup Boost Setup Limit off Turned Off  

Orders over $150 ship FREE!




Don't see what you're looking for?
Give us a call at (321) 725-3159 or email us at info@alamomotorsports.com