![]() |
|
The dominant king of boost controllers retains is throne! The new 20th-anniversary edition of the HKS EVC
boost controller is everything the last version and a whole lot more! Consider these features: |
|
|
|
MORE INFO ! |
|
| Part # | Description | Price |
| 45003-AK005 | HKS EVC Boost Controller Standard | $585.00 |
| 45003-AK007 | HKS EVC Boost Controller Limited Edition HKS 35th Anniversary with Yellow Display |
$585.00 |
| 45003-AK006 | HKS EVC Boost Controller Kit Includes Easy Writer Software |
$684.00 |
| 45003-AK009 **NEW!** |
HKS EVC-S Boost Controller Feature-rich entry-level electronic boost controller |
$418.00 |
| 53002-AK001 | HKS EVC Display Stand | $12.97ea |
Follow these simple setup steps:
Units of Measure - make sure you are selecting the correct unit of measure - PAS (kPa) or PSI.
Wastegate Type - (S) is for swing valve or internal (actuator) wastegate type or (P) is for poppet valve or external wastegate type
Standard Maximum Boost - is your "maximum" base wastegate spring pressure (NOT YOUR TARGET BOOST). It is recommended that you apply load to 3rd or 4th gear to obtain the base boost if you are not sure of your wastegate spring rate. An indicator will show your base boost where the P.H. is on the top of the screen. You can manually turn the knob also if you already know your base boost pressure.
Target Boost - this is where you would enter your target boost. The range is from base boost to 36 PSI. (This mode automatically sets your volume A and B, but you can change it after your initial set-up). ** You must set your target boost ABOVE your base wastegate spring rate and cannot be the same as your factory or base rate.
Initial Offset Value - the initial set-up offset value is different from the volume A and B offset settings. This step must be done to ensure you are obtaining your initial target boost. Your initial setting will be at 100%.
You will now need to apply load to 3rd or 4th gear again to check that you are obtaining your initial target boost. An indicator next to the P.H. will blink showing you a real time boost pressure reading. If you are not reaching your target boost, you will need to turn the percentage(%) gain up by turning the knob clockwise. If your boost is going over your target boost, you will need to turn the percentage (%) gain down by turning the knob counter clockwise. Once you've matched the target boost you will need to push the knob once to finish the initial set-up.
You are now done with your initial set-up and can now change from volume A and B by turning the knob left and right. To change the target boost for each setting, push the knob in once and turn the knob to your desired target boost, then push the knob once again to set it. That's it!